The priority order for QD75 to stop processing is as follows:
Deceleration stop < Sudden stop < Immediate stop (1) Deceleration (including automatic deceleration), even if the deceleration until the command turns ON or the deceleration stop occurs, the operation will stop at this deceleration speed.
(2) If the stop signal specified for the sudden stop turns ON or the cause of the stop occurs during the deceleration, the sudden stop processing is started from this point.
However, if the sudden stop deceleration time is longer than the deceleration time, the deceleration stop processing will continue even if a sudden stop cause occurs during the deceleration stop processing.
Mitsubishi plc input stop signal during deceleration (1) Even if the stop signal is input during deceleration (including automatic deceleration), the operation will stop at this deceleration speed.
(2) If a stop signal is input during deceleration of the OPR, the operation will stop at this deceleration speed. If you enter at creep speed, the run will stop immediately.
(3) If the specified stop cause is suddenly stopped during deceleration, the process will be abruptly stopped from that point.
The sudden stop processing during the deceleration is performed only when the sudden stop time is shorter than the deceleration stop time.