Mitsubishi PLC program uploads incomplete display yellow reason analysis - Database & Sql Blog Articles

0805 yellow

When uploading a program from a Mitsubishi plc to another PLC or computer, a lot of places in the program display a yellow background (pictured), and the Mitsubishi plc high version programming software is also useless. What is the reason? What about it? Generally speaking, it is a problem of programming methods. The following is a simple analysis of the reasons.
The reason why the Mitsubishi PLC program upload is incomplete is divided into two types:
1. One is to write a program on a computer. When the program is written in a serious error, it cannot be compiled and downloaded!
2. The other is to use a handheld programmer such as FX-20P-E. When there is an error in the overall structure of the program, it cannot be written into the PLC!
In both cases, the program cannot be uploaded, or the program upload is incomplete.
Mitsubishi PLC program upload incomplete solution
1. When writing a program on the computer, the back of the contact cannot exceed 24 lines, otherwise it can not be compiled, reminding the error.
2. When writing a program in the handheld programmer, it can exceed 24 lines without error. If the handheld programmer writes a program that exceeds 24 lines, when it is read by a computer program, the part that exceeds 24 lines will be lost, and the paragraph will have a yellow background color, and the program category is too large.