Uv Curving Glass,Tempered Glass Screen Protector,Film Cutting Machine,Uv Curing Protector Screen Shenzhen TUOLI Electronic Technology Co., Ltd. , https://www.szhydrogelprotector.com
PVC Insulation Power Cable
Name of Product:
- PVC insulated power cableÂ
- PVC cableÂ
- Pvc insulation and pvc sheath cableÂ
- Power cableÂ
- CE, ISO, CCC, UL, VDE certificate
PVC Insulated Power Cable:
Â
0.6/1 KV PVC insulated power cable is used for electric power transmission and distribution lines
Â
0.6/1 KV PVC insulated power cable
Â
1) Standard :IEC60502,GB/T 12706
Â
2).Voltage :0.6/1KV
Â
3).Specification:
Â
Type
Designation
Application
VV
Copper conductor ,PVC insulated ,PVC sheathed power cable
For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct
VLV
Aluminium conductor ,PVC insulated ,PVC sheathed power cable
VY
Copper conductor, PVC insulated, PE sheathed power cable
VLY
Aluminium conductor ,PVC insulated ,PE sheathed power cable
VV22
Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable
For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force
VLV22
Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable
VV23
Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable
VLV23
Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable
VV32
Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable
Â
For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces
VLV32
Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable
VV33
Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable
VLV33
Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable
Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied
Â
4).nominal cross-sectional areas:1.5 mm2Â , 2.5 mm2Â Â ,4 mm2Â , 6 mm2Â , 10 mm2Â Â , 16 mm2Â ,25 mm2Â Â , 35 mm2Â , 50 mm2Â Â ,70 mm2Â Â , 95 mm2Â Â ,120 mm2Â Â ,150 mm2Â ,185 mm2Â Â ,240 mm2Â ,300 mm2Â 400 mm2Â 500 mm2Â 630 mm2Â 800 mm2
Â
5)production range: single core cable from 1.5 mm2Â Â to 800 mm2,muli-core cable from 1.5 mm2Â Â to 400 mm2
Â
6).operating characteristics:
Rated power-frequency voltage u0/u:0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
Â
The anbient temperature under installations should not be below 0
Â
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter
Â