T Copper Tube Terminals,Non-Insulated Pin-Shaped Naked Terminal,Copper Cable Lugs Terminals,Insulated Fork Cable Spade Terminal Taixing Longyi Terminals Co.,Ltd. , https://www.longyicopperterminals.com
Â
Â
1.Product description:
(1) Conductor: Â Pure Copper/ CCA
(2) Type of the conductor: Â Solid/Stranded
(3) Insulation: Â Â PVC
(4) Normal of area: (1/2/3/4/5)x (1.0mm2Â - 70mm2)
(5) Voltage: Â Â Â 300/500V Â 450/750V 600/1000V
(6) Core color: Â Red, brown, green, yellow/green, black, blue, yellow, etc.
(7) Standard: Â Â BS6004
(8) Code name: Â BVV
Â
Â
2.Application:Â
Suitable for surface wiring, indoor or outdoor.Â
Â
4.Technical Data:BVV
Core number* nominal cross section
mm2
Conductor type
Rated value of sheath thickness
mm
Rated value of sheath thickness
mmUpper Value of average overall diameter
mmMinimum insulation resistance under temperature 700C
 MΩ.kmÂ
Â
2×1.5
1
0.7
1.2
10.0
0.011
Â
2
0.7
1.2
10.5
0.010
Â
2×2.5
1
0.8
1.2
11.5
0.010
Â
2
0.8
1.2
12.0
0.009
Â
2×4
1
0.8
1.2
12.5
0.0085
Â
2
0.8
1.2
13.0
0.0077
Â
2×6
1
0.8
1.2
13.5
0.0070
Â
2
0.8
1.2
14.0
0.0065
Â
2×10
1
1.0
1.4
16.5
0.0070
Â
2
1.0
1.4
17.5
0.0065
Â
2×16
2
1.0
1.4
20.0
0.0052
Â
2×25
2
1.2
1.4
24.0
0.0050
Â
2×35
2
1.2
1.6
27.5
0.0044
Â
3×1.5
1
0.7
1.2
10.5
0.011
Â
2
0.7
1.2
11.0
0.010
Â
3×2.5
1
0.8
1.2
12.0
0.010
Â
2
0.8
1.2
12.5
0.009
Â
3×4
1
0.8
1.2
13.0
0.0085
Â
2
0.8
1.2
13.5
0.0077
Â
3×6
1
0.8
1.4
14.5
0.0070
Â
2
0.8
1.4
15.5
0.0065
Â
3×10
1
1.0
1.4
17.5
0.0070
Â
2
1.0
1.4
19.5
0.0065
Â
3×16
2
1.0
1.4
21.5
0.0052
Â
3×25
2
1.2
1.4
26.0
0.0050
Â
3×35
2
1.2
1.6
29.0
0.0044
Â
4×1.5
1
0.7
1.2
11.5
0.011
Â
2
0.7
1.2
12.0
0.010
Â
4×2.5
1
0.8
1.2
13.0
0.010
Â
2
0.8
1.2
13.5
0.009
Â
4×4
1
0.8
1.4
14.5
0.0085
Â
2
0.8
1.4
15.0
0.0077
Â
4×6
1
0.8
1.4
16.0
0.0070
Â
2
0.8
1.4
17.0
0.0065
Â
4×10
1
1.0
1.4
19.0
0.0070
Â
2
1.0
1.4
20.5
0.0065
Â
4×16
2
1.0
1.4
23.5
0.0052
Â
4×25
2
1.2
1.6
27.5
0.0050
Â
4×35
2
1.2
1.6
32.0
0.0044
Â
5×1.5
1
0.7
1.2
12.0
0.011
Â
2
0.7
1.2
12.5
0.010
Â
5×2.5
1
0.8
1.2
14.0
0.010
Â
2
0.8
1.2
14.5
0.009
Â
5×4
1
0.8
1.4
16.0
0.0085
Â
2
0.8
1.4
17.0
0.0077
Â
5×6
1
0.8
1.4
17.5
0.0070
Â
2
0.8
1.4
18.5
0.0065
Â
5×10
1
1.0
1.4
21.0
0.0070
Â
2
1.0
1.4
22.0
0.0065
Â
5×16
2
1.0
1.6
26.0
0.0052
Â
5×25
2
1.2
1.6
31.5
0.0050
Â
5×35
2
1.2
1.6
35.0
0.0044
Â
     2.Insulator:PVC/C type PVC mixture is adopted as insulating material.
     3.Sheath:PVC/ST4 model PVC mixture should be adopted as the inner sheath.
     4.The average overall diameter should be within the limitation stipulation of the table.
FAQ:
Q1. What kind of products can your company supply?Â
A: We specialize in supplying network cable, coaxial cable, power cable ,control cable , telephone cable, speaker cable and ect. Â
Â
Q2. What's your MOQ?
A: The MOQ of long meter cable is 50 km, or we can negociate. Â
Â
Q3. What's your delivery time?Â
A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.Â
Â
Q4. What are your payment terms?
A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.Â
Â
Q5. What's your trade term ?Â
A: We can accept FOB, CIF, EXW term. Â
Â
Q6. What's your conventional packing ?
A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.Â
Â
Q7. Can your factory customize cables based on clients' samples or data sheet ?Â
A: Yes, we can.
Â
Q8. Can you offer me a free sample?
A: Yes, we do, that is a start of business I think, and you will only pay the cost of delivery, which we will return it to you when you put the order.
Â
Â
Â
1.Product description:
(1) Conductor: Â Pure Copper/ CCA
(2) Type of the conductor: Â Solid/Stranded
(3) Insulation: Â Â PVC
(4) Normal of area: (1/2/3/4/5)x (1.0mm2Â - 70mm2)
(5) Voltage: Â Â Â 300/500V Â 450/750V 600/1000V
(6) Core color: Â Red, brown, green, yellow/green, black, blue, yellow, etc.
(7) Standard: Â Â BS6004
(8) Code name: Â BVV
Â
Â
2.Application:Â
Suitable for surface wiring, indoor or outdoor.Â
Â
4.Technical Data:BVV
Core number* nominal cross section
mm2
Conductor type
Rated value of sheath thickness
mm
Rated value of sheath thickness
mmUpper Value of average overall diameter
mmMinimum insulation resistance under temperature 700C
 MΩ.kmÂ
Â
2×1.5
1
0.7
1.2
10.0
0.011
Â
2
0.7
1.2
10.5
0.010
Â
2×2.5
1
0.8
1.2
11.5
0.010
Â
2
0.8
1.2
12.0
0.009
Â
2×4
1
0.8
1.2
12.5
0.0085
Â
2
0.8
1.2
13.0
0.0077
Â
2×6
1
0.8
1.2
13.5
0.0070
Â
2
0.8
1.2
14.0
0.0065
Â
2×10
1
1.0
1.4
16.5
0.0070
Â
2
1.0
1.4
17.5
0.0065
Â
2×16
2
1.0
1.4
20.0
0.0052
Â
2×25
2
1.2
1.4
24.0
0.0050
Â
2×35
2
1.2
1.6
27.5
0.0044
Â
3×1.5
1
0.7
1.2
10.5
0.011
Â
2
0.7
1.2
11.0
0.010
Â
3×2.5
1
0.8
1.2
12.0
0.010
Â
2
0.8
1.2
12.5
0.009
Â
3×4
1
0.8
1.2
13.0
0.0085
Â
2
0.8
1.2
13.5
0.0077
Â
3×6
1
0.8
1.4
14.5
0.0070
Â
2
0.8
1.4
15.5
0.0065
Â
3×10
1
1.0
1.4
17.5
0.0070
Â
2
1.0
1.4
19.5
0.0065
Â
3×16
2
1.0
1.4
21.5
0.0052
Â
3×25
2
1.2
1.4
26.0
0.0050
Â
3×35
2
1.2
1.6
29.0
0.0044
Â
4×1.5
1
0.7
1.2
11.5
0.011
Â
2
0.7
1.2
12.0
0.010
Â
4×2.5
1
0.8
1.2
13.0
0.010
Â
2
0.8
1.2
13.5
0.009
Â
4×4
1
0.8
1.4
14.5
0.0085
Â
2
0.8
1.4
15.0
0.0077
Â
4×6
1
0.8
1.4
16.0
0.0070
Â
2
0.8
1.4
17.0
0.0065
Â
4×10
1
1.0
1.4
19.0
0.0070
Â
2
1.0
1.4
20.5
0.0065
Â
4×16
2
1.0
1.4
23.5
0.0052
Â
4×25
2
1.2
1.6
27.5
0.0050
Â
4×35
2
1.2
1.6
32.0
0.0044
Â
5×1.5
1
0.7
1.2
12.0
0.011
Â
2
0.7
1.2
12.5
0.010
Â
5×2.5
1
0.8
1.2
14.0
0.010
Â
2
0.8
1.2
14.5
0.009
Â
5×4
1
0.8
1.4
16.0
0.0085
Â
2
0.8
1.4
17.0
0.0077
Â
5×6
1
0.8
1.4
17.5
0.0070
Â
2
0.8
1.4
18.5
0.0065
Â
5×10
1
1.0
1.4
21.0
0.0070
Â
2
1.0
1.4
22.0
0.0065
Â
5×16
2
1.0
1.6
26.0
0.0052
Â
5×25
2
1.2
1.6
31.5
0.0050
Â
5×35
2
1.2
1.6
35.0
0.0044
Â
     2.Insulator:PVC/C type PVC mixture is adopted as insulating material.
     3.Sheath:PVC/ST4 model PVC mixture should be adopted as the inner sheath.
     4.The average overall diameter should be within the limitation stipulation of the table.
FAQ:
Q1. What kind of products can your company supply?Â
A: We specialize in supplying network cable, coaxial cable, power cable ,control cable , telephone cable, speaker cable and ect. Â
Â
Q2. What's your MOQ?
A: The MOQ of long meter cable is 50 km, or we can negociate. Â
Â
Q3. What's your delivery time?Â
A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.Â
Â
Q4. What are your payment terms?
A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.Â
Â
Q5. What's your trade term ?Â
A: We can accept FOB, CIF, EXW term. Â
Â
Q6. What's your conventional packing ?
A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.Â
Â
Q7. Can your factory customize cables based on clients' samples or data sheet ?Â
A: Yes, we can.
Â
Q8. Can you offer me a free sample?
A: Yes, we do, that is a start of business I think, and you will only pay the cost of delivery, which we will return it to you when you put the order.
Â
Electric Cable 1mm 2 Core Copper Conductor PVC Insulated and Sheathed BVV Electrical Single Core Cable
Model NO.: BVV
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: CE, CCC, RoHS
Brand: Sansen
Trademark: OEM
Transport Package: as Requirement
Specification: H07V-U, 0.5mm 0.75m1.5mm 2.5mm 4mm 6mm 10mm 16mm.
Origin: China
HS Code: 854449110
Model NO.: BVV
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: CE, CCC, RoHS
Brand: Sansen
Trademark: OEM
Transport Package: as Requirement
Specification: H07V-U, 0.5mm 0.75m1.5mm 2.5mm 4mm 6mm 10mm 16mm.
Origin: China
HS Code: 854449110
Â
Flat cable BVV Solid Conductor PVC Insulation PVC CableÂ
Flat cable BVV Solid Conductor PVC Insulation PVC Cable