For the Curved Led Screen, if you use the traditional horizontal led module that can take a lot of problems such as large seams, the Curved LED screen screen cabinet body arc is not smooth, cannot adapt to large arc situations. Therefore, in order to ensure that, we would like to use the vertical led module to achieve better smoothness on the surface, and easy to assembly into a large arc curved Led Screen.
Curved LED screen Curved Led Screen,Arc-Shaped Led Display,Rental Led Display Screen,Curved Led Display Screen Shenzhen Cxcolor Optoelectronics Co., LTD. , http://www.largeledscreen.com
Original Meanwell CLG-100 Series Single Output Waterproof IP67 LED Driver Features:
1. Universal AC input / Full range (up to 295VAC)
2. Built-in active PFC function
3. High efficiency up to 89%
4. Protections: Short circuit / Over current / Over voltage / Over temperature
5. Cooling by free air convection
6. IP67 design for indoor or outdoor installations
7. Class 2 power unit
8. Pass LPS
9. 100% full load burn-in test
10. High reliability
11. Suitable for LED lighting and moving sign applications (Note.2)
12. Compliance to worldwide safety regulations for lighting
13. Suitable for dry / damp / wet locations
14. 3 years warranty
Original Meanwell CLG-100 Series Single Output Waterproof IP67 LED Driver Specifications:
Â
MODEL
CLG-100-12
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.7
9 ~ 12V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
20.25 ~ 27V
27 ~ 36V
36 ~ 48V
RATED CURRENTÂ Â Â Â Â Â Â Note.5
5A
5A
4.8A
4A
3.55A
2.65A
2A
RATED POWERÂ Â Â Â Â Â Â Â Â Â Â Note.5
60W
75W
96W
96W
95.85W
95.4W
96W
RIPPLE & NOISE (max.) Note.2
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±2.0%
SETUP, RISE TIME
500ms, 80ms / 230VACÂ Â Â 1200ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)
60ms / 230VACÂ Â Â 30ms / 115VAC at full load
INPUT
VOLTAGE RANGEÂ Â Â Â Â Â Â Note.4
90 ~ 295VACÂ Â Â 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.)
83%
85%
88.5%
88.5%
88%
88%
88.5%
AC CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VACÂ Â Â 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
INRUSH CURRENT(Typ.)
COLD START 40A(twidth=1030μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
PROTECTION
OVER CURRENT (Typ.)
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
39 ~ 48V
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
-30 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80ºC, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ºC (0 ~ 50ºC)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMCSAFETY STANDARDSÂ Â Note.8
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), TUV EN60950-1, IP67, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>=75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS
MTBF
301Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION
222.2*68*38.8mm (L*W*H)
PACKING
1.0Kg; 12pcs/13Kg/0.58CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68ºC.
7. Please refer to "DRIVING METHODS OF LED MODULE".
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
Â